Bonfire Requirements

Permission Required

An online request form shall be submitted to the Fire Marshal’s office for approval of all bonfires. This form can be found here. Once submitted, the Fire Marshal’s office will either approve or deny the request and notify the applicant at the email address provided.

Location

The location for any open burning shall not be less than fifty (50) feet from any structure, and provisions shall be made to prevent the fire from spreading to within fifty (50) feet of any structure. Fires in approved containers shall be permitted, provided that such fires are not less than fifteen (15) feet from any structure.

Attendance

Any open burning shall be constantly attended until the fire is extinguished. At least one portable fire extinguisher with a minimum 4-A rating, two portable fire extinguishers with a minimum 2-A rating each, or other approved on-site fire extinguishing equipment, such as a garden hose, shall be available for immediate utilization.

Bonfire size and duration

A bonfire shall not be more than five feet by five feet by five feet (5'x5'x5') in dimension and shall not burn longer than three (3) hours.

Material

Fuel for a bonfire shall consist only of seasoned dry firewood and shall be ignited with a small quantity of paper. The fire shall not be utilized for waste disposal purposes, and the fuel shall be chosen to minimize the generation of air contaminants.